l-blue
Ask us a question...
Telephone +44 (0) 1403 210204 Safeguard - Making Buildings Dry

Waterproofing Piled Foundations

The waterproofing of concrete-piled foundations presents a problem for many waterproofing systems - particularly those based on sheet membranes. The majority of these systems cannot be used over pile heads and pile caps because they do not have the bearing capacity to support the applied load.

Vandex Super crystalline active waterproofing slurry offers a solution to this problem. Because its waterproofing action relies on penetrating into the concrete pile head or pile cap rather than forming a waterproof layer on top of the concrete, it is able to accept the load applied by subsequently poured ground beams or foundation slabs.

Vandex Super can either be used in its own right to provide a complete foundation waterproofing solution or combined with other waterproofing systems. Each 25Kg bag of Vandex Super waterproofs up to 20m2 so it is extremely economical in use.

An example of a typical application is shown below, however, because piled foundations vary widely in their configuration it is strongly recommended that our technical department are consulted early in the design process.

Example 1 - Waterproofing of Pile Head and Ground Beam

Waterproofing pile heads and ground beam

  1. Slurry coat the piles with VANDEX SUPER 1.5 kg/m² applied in two coats.
  2. Dry sprinkle VANDEX SUPER at the rate of 1.2 kg/m² to the blinding concrete prior to the concrete pour.
  3. Apply VANDEX EXPASEAL 2520 circular around the piles in the middle of the slab.
  4. After pouring the concrete slab dry sprinkle VANDEX SUPER at the rate of 1.2 kg/m² on top of the raft foundation when the concrete reaches initial set. It is then troweled in until coverage is uniform and the specific finish is achieved. Alternatively slurry coat the horizontal surface with VANDEX SUPER 1.2 kg/m² in one coat.

Related Applications

Waterproofing Concrete Slabs - Use of Vandex Super and Oldroyd cavity drainage membranes to prevent water ingress through new concrete slabs.

Waterproofing Basement Retaining Walls - Waterproofing contiguously piled, secant piled, and diaphragm basement walls.

Waterproofing Newbuild Basements - Use of a "dual layer" externally applied waterproofing system to waterproof newbuild basements where access to the external face of the basement walls is possible.

RIBA-Approved CPD Seminars

Safeguard currently offer the following RIBA-Approved CPD Seminars free-of-charge to architects and specifiers on the UK mainland:

Constructing a Pile Cap
Constructing a pile cap
 
Download Datasheets
Vandex Super Flyer Vandex Dry Sprinkle Vandex Super
Vandex Super Flyer (248k) Vandex Super Dry Sprinkle (280k) Vandex Super datasheet (28k)
Vandex Super Vandex Premix Vandex Concrete Grey
Vandex BB75 (28k) Vandex Premix (28k) Vandex Concrete Grey (28k)
Vandex Super BBA Vandex - concrete waterproofing and protection Price List
Vandex Super BBA (125k) Vandex General Leaflet (1.7Mb) Price List & Order Form (85k)
Adobe Acrobat Reader is required to view these datasheets (available free from the Adobe website.) p
[Click Here] to request a copy of any of these publications by post.

Technical Support

The following technical support features are available through this website:

To speak to a member of our technical team call 01403 210204 during office hours.
Bookmark and Share
Vandex
odlroyd
Stormdry
Dryzone

Safeguard Europe Limited provides information on this web site for your personal use. Access and use of the information is subject to the terms and conditions displayed on the site and all applicable laws. By accessing, and using information on, this web site, you accept and agree to be bound by these terms and conditions. We strongly recommend that you contact us directly for further help and guidance on all aspects of our products and services.

©Safeguard Europe Limited, Horsham, West Sussex, UK, RH13 5QL. All Rights Reserved. Registered in England and Wales. Company Number 1721203.

[Site Map]